US V1.3 Cells -Curious Results and Next Steps
While the EU Cells were switched to a pure differential mode so they could run at higher pressure and more autonomously while Mathieu travels, the US cells are sticking to the V2.0 protocol so far. We are on Step 8 and seeing some results this morning that I just have to run by the crowd and get opinions on.
Below is the data set from the beginning of step 8 of the V2.0 protocol, in which we loaded the active wire, again, and then heated directly with 25.0 W. The noteworthy features of this graph are:
- The Resistance of the wire rises in a few different slopes.
- The vacuum level of the cell drops in a pretty close mirror of the resistance of the wire
- The T_Ext and the T_mica both rise way above where they settle when the vacuum level and the resistance have settled. The T_mica peaks where the resistance rise becomes more gradual.
- For about 8 hours the T_Ext temperature was elevated.
- The indicated power out maxed out at 1.8W, but settled at ~1.0W
So, for energy output, it was very much in line with the performance during the previous passive heated part of the test. The story I am getting is that the hydrogen leaves the wire and the vacuum pump tries to keep pumping it out. That is fascinating, itself.
The Potential explanations for the higher temperatures are:
- It is either the presence of Hydrogen, or the few extra millibar, or both that is causing different thermal conductivity.
- Or the Hydrogen leaving the wire monotomically is recombining and releasing that chemical energy.
- Or possibly, the flux of hydrogen out of the wire along with the current and heat in the wire is causing a LENR reaction till the hydrogen runs out.
The trick, now, is to try to separate the physical and chemical effect from any LENR effect. One potential test I can imagine is to remove the Celani wire and run a control with the NiChrome and some hydrogen. What would come after that? After removing the active wire in cell A, we could later run in differential mode like the EU cells and try a range of pressures and power levels and see if we can find more obvious results.
What other tests would help us sort this out?
Comments
settling at a still relatively low value[actually it appears it's increasing more or less linearly at the moment, although at a rather slow rate], the active wire in US Cell A must be receiving a very limited amount of heat through small patches in contact with the mica support and through some heat radiation by the Ni-Cr wire.07/15/2013 12:00:00 07/15/2013 23:23:48
US 1.3B -- Pb(bar) shows .01 ... do you see something different?
It seems that pulling the stronger vac on US1.3B is increasing the temps, is that expected? I guess I could see the mica temp going up, but the ext temps as well?
Well, part of the MiniProject is to put across some of our ideas and get you guys to critique it / suggest ways to optimise it.
Excellent, I am excited. Do you have an order of magnitude feel for the cost of making one? Thanks.
We are readying our latest designs for the sequel to the Steel and Glass, for a mini project to let you guys let rip. It will be very flexible, allowing for single and dual chambers, flow through, fluid calorimetry, arc/glow and RF triggering.
Bob
Using, different lengths of active heating wire in the two cells (say ratio of 1:3) should enable other spurious excess energy results not linked to gas pressure rise to be de-convolved from the LENR effect.
@Ecco
The cells could also be coated with black ceramic paint.
That is an excellent idea.
You know, if we could demonstrate that the hydrogen remains in the wire under high pressure inert gas, it might be possible to do side by side tests with inert gas in both cells.
Prepare the two cells, one with a hydrogen loaded wire and the other without
An option to prevent this from happening could be to not start the test I previously proposed as soon as the wire is loaded, but to apply power under dynamic vacuum for a while first. I believe most of the hydrogen gets outgassed during this phase, when active wire resistance increases (EDIT: corrected) the most.
Do you think that the out-gassing would occur even if the inert gas pressure was very high?
If you did that we could check to see if the pressure drops as it did with hydrogen. I understand that the atoms of H are much smaller but still, if there's a drop in pressure with the inert gas then we can make some assumptions about hydrogen.
- Quickly reload Cell A in H2
- Once the wire has loaded, power the cell off
- Flush Cell A and Cell B from their current gases, then fill them with Helium at low pressure, while power is still off. Do this a couple times.
- Apply vacuum again, connect both cells' vacuum lines together (as in EU Cells)
- Apply power again
This test should clear at least in part issues about the difference in thermal conductivity of the residual gases.
However, Cell A will keep outgassing hydrogen under load and this might interfere with this test.
RSS feed for comments to this post