			<description><![CDATA[I would like to focus an issue pointed out by ECCO (#1 2012-10-16 16:42) because it's important and many skeptics criticize the Celani's work only on that thesis (parasitic thermal masses near the cell increase his temperature). In order to avoid (or reduce) that, would be useful: a) using taller lateral supports that increase the vertical distance between the cell and the horizontal support; b) using not metallic supports or, alternatively, build them with thin rods instead of "full" metal; c) the same for the horizontal support. It shouldn't be metallic or should be covered with materials that don't accumulate heat or that don't reflect heat toward the cell; d) performing calibrations for long periods of time (many days) in order to estimate if the problem exists. In particular long time calibrations are very important to see if there is a thermal drift and to estimate the influence of the room temperatures in the day/night cycle.]]></description>
			<dc:creator>bg</dc:creator>
			<pubDate>Thu, 18 Oct 2012 09:02:36 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-53</guid>
		</item>
		<item>
			<title>Ryan Hunt says:</title>
			<link>http://www.quantumheat.org#comment-49</link>
			<description><![CDATA[Dave, that question has come up a couple times today. I think to do that we will have to arrange to have a small voltage on the unpowered wire and measure the resulting current. It should be possible and I think it is a good idea. Ecco, for the time being we are focused on just replicating a simple experiemnt with hydrogen and will leave the derivative experiments like playing with dueterium to the researchers we will hopefully inspire.]]></description>
			<dc:creator>Ryan Hunt</dc:creator>
			<pubDate>Wed, 17 Oct 2012 04:00:20 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-49</guid>
		</item>
		<item>
			<title>Ecco says:</title>
			<link>http://www.quantumheat.org#comment-48</link>
			<description><![CDATA[Nice. Do you plan using Deuterium too? In his ICCF17 presentation, Celani reported that first the reactor acted endothermically during the first hours of activity, but then eventually became exothermic (production of excess heat). Also, with Deuterium, he detected X-ray burst activity after the loading phase, when applying power. That will be extremely interesting to see and check out.]]></description>
			<dc:creator>Ecco</dc:creator>
			<pubDate>Tue, 16 Oct 2012 20:19:27 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-48</guid>
		</item>
		<item>
			<title>Dave Roberson says:</title>
			<link>http://www.quantumheat.org#comment-47</link>
			<description><![CDATA[Is it possible to get a measurement of the temperature of the second wire when the other one is driven? Celani kept a record of R/R0 to give him a reference. This is important because we need to know how much equivalent power is applied to the CONSTANTAN by virtue of being close to the NICHROME wire. As example, if 50 watts is applied to the inactive wire, does the active one get heated as though it had 10 watts applied? I would like to attempt to separate hydrogen gas temperature versus wire temperature effects on the excess power.]]></description>
			<dc:creator>Dave Roberson</dc:creator>
			<pubDate>Tue, 16 Oct 2012 17:35:59 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-47</guid>
		</item>
		<item>
			<title>Ryan Hunt says:</title>
			<link>http://www.quantumheat.org#comment-46</link>
			<description><![CDATA[The active wire is enroute from Europe. The configuration right now is two .2mm nichrome wires. Helium has a thermal conductivity very close to hydrogen. We are planning to be able to charge the chamber with Hydrogen and/or Argon.]]></description>
			<dc:creator>Ryan Hunt</dc:creator>
			<pubDate>Tue, 16 Oct 2012 16:48:50 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-46</guid>
		</item>
		<item>
			<title>Ecco says:</title>
			<link>http://www.quantumheat.org#comment-45</link>
			<description><![CDATA[Thanks, that should help dispelling some criticisms with this set-up. By the way, if I understood correctly, both NiCr and Active Constantan wires are in the reactor right now? Is it ok to apply that much power directly to the active wire? It might not be the case of Helium (which I think you are using right now), but Celani limits input power to 30 watts when using Argon gas due to sintering problems when applying high power to the active wire under such gas (used by him in 100% concentration during the calibration phase). In general it looks like you're using a much higher input power than what Celani has shown in his slides so far (where the limit was 48W. He performs calibration at steps of 5, 15, 30 and 48 watts) Please disregard if you're not using an active wire yet inside the reactor.]]></description>
			<dc:creator>Ecco</dc:creator>
			<pubDate>Tue, 16 Oct 2012 16:42:27 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-45</guid>
		</item>
		<item>
			<title>Ryan Hunt says:</title>
			<link>http://www.quantumheat.org#comment-44</link>
			<description><![CDATA[We should have such a time from midnight and 8 am Monday (CST) at max power we can examine for that.]]></description>
			<dc:creator>Ryan Hunt</dc:creator>
			<pubDate>Tue, 16 Oct 2012 15:35:01 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-44</guid>
		</item>
		<item>
			<title>Ecco says:</title>
			<link>http://www.quantumheat.org#comment-43</link>
			<description><![CDATA[There have been concerns that over a long period of time (many hours to days), at a constant input power, reactor temperatures would [very] slowly increase due to heat stored on the work bench being irradiating back to the reactor, or something like this. This (according to proponents of this theory) would cause the apparent increase of excess heat effect over time shown by the Celani reactor. Are you able to produce a graph of reactor temperatures at a constant input temperature over many hours? For the sake of avoiding controversies, next time you will perform a calibration run also try making each calibration step completely stabilized in temperatures at least in the short term.]]></description>
			<dc:creator>Ecco</dc:creator>
			<pubDate>Tue, 16 Oct 2012 07:53:56 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-43</guid>