<?xml version="1.0" encoding="utf-8"?>
<rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:atom="http://www.w3.org/2005/Atom">
	<channel>
		<title>QuantumHeat.org</title>
		<description>Discuss QuantumHeat.org</description>
		<link>http://www.quantumheat.org</link>
		<lastBuildDate>Tue, 12 May 2026 16:12:02 +0000</lastBuildDate>
		<generator>JComments</generator>
		<atom:link href="http://www.quantumheat.org/index.php/de/component/jcomments/feed/com_content/503" rel="self" type="application/rss+xml" />
		<item>
			<title>Toyota samarinda says:</title>
			<link>http://www.quantumheat.org#comment-8600</link>
			<description><![CDATA[Hello, its good paragraph about media print, we all understand media is a impressive source of facts.]]></description>
			<dc:creator>Toyota samarinda</dc:creator>
			<pubDate>Tue, 07 Jun 2016 14:37:50 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-8600</guid>
		</item>
		<item>
			<title>Alan Smith says:</title>
			<link>http://www.quantumheat.org#comment-7194</link>
			<description><![CDATA[I am a big fan of simple and elegant experiments simply and elegantly explained. And this is certainly a fine example. I shall follow this thread (or should I say wire) with interest.]]></description>
			<dc:creator>Alan Smith</dc:creator>
			<pubDate>Fri, 04 Dec 2015 20:54:33 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-7194</guid>
		</item>
		<item>
			<title>EccoEcco says:</title>
			<link>http://www.quantumheat.org#comment-7193</link>
			<description><![CDATA[@MFMP: in light of the document just published / update, this blogpost deserves a bump so that it will be easier to find in the "Experiments and updates" list on the right.]]></description>
			<dc:creator>EccoEcco</dc:creator>
			<pubDate>Fri, 04 Dec 2015 17:38:50 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-7193</guid>
		</item>
		<item>
			<title>Ecco says:</title>
			<link>http://www.quantumheat.org#comment-6966</link>
			<description><![CDATA[@Mathieu Valat: ok, I see. Thanks.]]></description>
			<dc:creator>Ecco</dc:creator>
			<pubDate>Tue, 22 Sep 2015 14:45:01 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-6966</guid>
		</item>
		<item>
			<title>Mathieu Valat says:</title>
			<link>http://www.quantumheat.org#comment-6965</link>
			<description><![CDATA[Celani is cautious about using helium. He said it would make available sites for hydrogen adsorption filled with an unwanted material. That is part of why he uses xenon.]]></description>
			<dc:creator>Mathieu Valat</dc:creator>
			<pubDate>Tue, 22 Sep 2015 14:29:21 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-6965</guid>
		</item>
		<item>
			<title>Ecco says:</title>
			<link>http://www.quantumheat.org#comment-6964</link>
			<description><![CDATA[@Mathieu Valat: thanks for answering. Actually I was curious to know if at some point you could also test H2/He gas mixtures to see how results would compare against pure hydrogen.]]></description>
			<dc:creator>Ecco</dc:creator>
			<pubDate>Tue, 22 Sep 2015 13:50:54 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-6964</guid>
		</item>
		<item>
			<title>Mathieu Valat says:</title>
			<link>http://www.quantumheat.org#comment-6963</link>
			<description><![CDATA[ I am discussing a deal to get a mass-flow controller for the mass-flow calorimeter. This will replace the FMI pump used for the water circulation loop. This sponsor will be disclosed in due time. We are adjusting the latest details. I'll keep you updated. Not at that time, but there is helium available on the bench.]]></description>
			<dc:creator>Mathieu Valat</dc:creator>
			<pubDate>Tue, 22 Sep 2015 13:34:51 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-6963</guid>
		</item>
		<item>
			<title>Ecco says:</title>
			<link>http://www.quantumheat.org#comment-6961</link>
			<description><![CDATA[@Robert Greenyer: good! How powerful will the new pump be? Are there plans using different gas mixtures?]]></description>
			<dc:creator>Ecco</dc:creator>
			<pubDate>Tue, 22 Sep 2015 09:57:58 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-6961</guid>
		</item>
		<item>
			<title>Robert Greenyer says:</title>
			<link>http://www.quantumheat.org#comment-6960</link>
			<description><![CDATA[@Ecco I have the latest version and am proof reading it today. Celani is preparing us some wires as I write this for the MFC (which is waiting on a new pump) and the dual cells / gamma test.]]></description>
			<dc:creator>Robert Greenyer</dc:creator>
			<pubDate>Tue, 22 Sep 2015 08:35:09 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-6960</guid>
		</item>
		<item>
			<title>Ecco says:</title>
			<link>http://www.quantumheat.org#comment-6957</link>
			<description><![CDATA[@Bob: I think he means that he wrapped all his wires (which were already being individually wrapped in borosilicate glass fibers - ie: E-glass) with an additional sleeve made of pure alumina glass fibers. http://i.imgur.com/Gvvjnwe.jpg http://i.imgur.com/Gvvjnwe.jpg Source: http://www.francescocelanienergy.org/files/Art.ICCF19_100915H3_Aggiornato.pdf EDIT: @MFMP: I think this is the latest updated version of his ICCF19 paper, but this time with photos and diagrams. http://www.francescocelanienergy.org/files/Art.ICCF19_100915H3_Aggiornato.pdf]]></description>
			<dc:creator>Ecco</dc:creator>
			<pubDate>Mon, 21 Sep 2015 18:20:03 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-6957</guid>
		</item>
		<item>
			<title>bob says:</title>
			<link>http://www.quantumheat.org#comment-6956</link>
			<description><![CDATA[I see from the preprint of Celani's ICCF-19 paper on the MFMP facebook site that Celani's 3rd generation apparatus replaces the glass tube with Al2O3 one. This is very interesting because it would affect the IR radiative transmission from wire to ambient in significant way. It is a small step from a single Al2O3 tube to a concentric double tube which would make a very usable conduction calorimeter. Is anyone in the MFMP family planning to replicate this latest Celani device?]]></description>
			<dc:creator>bob</dc:creator>
			<pubDate>Mon, 21 Sep 2015 18:13:51 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-6956</guid>
		</item>
		<item>
			<title>Ecco says:</title>
			<link>http://www.quantumheat.org#comment-6822</link>
			<description><![CDATA[Are the next Celani wire replications from MFMP going to use lithium in enough amount as to wet the entire active wire? I think one would probably have to come up with a different cell design for this, however.]]></description>
			<dc:creator>Ecco</dc:creator>
			<pubDate>Wed, 02 Sep 2015 08:22:46 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-6822</guid>
		</item>
	</channel>
</rss>
