		<item>
			<title>Edwin Pell says:</title>
			<link>http://www.quantumheat.org#comment-4074</link>
			<description><![CDATA[How about voltage variation from the power company? For the 24 hour cycle.]]></description>
			<dc:creator>Edwin Pell</dc:creator>
			<pubDate>Tue, 13 Aug 2013 18:59:49 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-4074</guid>
		</item>
		<item>
			<title>Wes Baish says:</title>
			<link>http://www.quantumheat.org#comment-4072</link>
			<description><![CDATA[@RIck Cantwell we use Omegadyne PX-309 transducers (http://www.omegadyne.com/ppt/prod.html?ref=PX309&flag=1) which employ the use of silicon strain sensors. The unit's temperature is well isolated from the rest of the cell's operating temp and typically couples well to ambient temperature cycling, though it's tough to observe in the current data. We've been entertaining the idea that we're paying too close attention to a pressure sensor with a limited resolution. Additionally it might not hold up well in a hydrogen atmosphere. Hydrogen diffusion through the silicon sensor membrane should be pretty poor, shouldn't it?]]></description>
			<dc:creator>Wes Baish</dc:creator>
			<pubDate>Tue, 13 Aug 2013 16:37:20 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-4072</guid>
		</item>
		<item>
			<title>Paul Hunt says:</title>
			<link>http://www.quantumheat.org#comment-4065</link>
			<description><![CDATA[Perhaps we could plumb a second pressure sensor into the line and monitor both of them. If the pressure drop is real, it will show up in both sensors. Otherwise it is probably a phenomenon inside the sensor.]]></description>
			<dc:creator>Paul Hunt</dc:creator>
			<pubDate>Sun, 11 Aug 2013 05:15:26 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-4065</guid>
		</item>
		<item>
			<title>Ryan Hunt says:</title>
			<link>http://www.quantumheat.org#comment-4062</link>
			<description><![CDATA[We haven't, yet, been able to figure out any instrumentation scenario that would cause this. We are still looking, but it appears to be something really happening on the pressure.]]></description>
			<dc:creator>Ryan Hunt</dc:creator>
			<pubDate>Fri, 09 Aug 2013 21:06:24 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-4062</guid>
		</item>
		<item>
			<title>btbbass says:</title>
			<link>http://www.quantumheat.org#comment-4056</link>
			<description><![CDATA[Super dense H2 cluster formation? Of course, sensor artifact should be excluded first...]]></description>
			<dc:creator>btbbass</dc:creator>
			<pubDate>Fri, 09 Aug 2013 08:27:05 +0000</pubDate>
			<guid>http://www.quantumheat.org#comment-4056</guid>